We stick to our enterprise spirit of "Quality, Performance, Innovation and Integrity". We purpose to create a lot more price for our prospects with our rich resources, innovative machinery, experienced workers and great products and services for cable test termination system, Lan Cable Drawing Line , Compounding Line , data cable making machine , should you have any query or wish to place an initial order please do not hesitate to contact us. We now have a specialist, efficiency workforce to deliver excellent service for our purchaser. We always follow the tenet of customer-oriented, details-focused for cable test termination system, We will supply much better products with diversified designs and professional services. At the same time, welcome OEM, ODM orders, invite friends at home and abroad together common development and achieve win-win, integrity innovation, and expand business opportunities! If you have any question or need more information please feel free to contact us. We are looking forward to receiving your enquiries soon.


  • Power Cable Test Termination

    Power Cable Test Termination

    1. Introduction For power cable PD test, AC test, impulse test, tan delta test, etc. 2. Technical Parameters There are two types: 1. Oil test terminal (for XLPE cables under 35KV). 2. Deionized water terminal (for XLPE cables under 66KV-500KV). The water terminal consists of epoxy resin out and inter tube. The water at HV side cycles in the inner tube around the cable and back to outer tube. The terminal is fixed on movable base by bearing and hydraulic unit, and can rise to 45° for test. Cal...
  • Low price for Online Laser Diameter Gauge -
 Tanδ Measuring Bridge – LINT TOP

    Low price for Online Laser Diameter Gauge - Tanδ Measuring Bridge – LINT TOP

    1. Introduction The system is used for HV cable, power transformer, HV switch and so on. It judges quality of test sample by HV Tanδ test to improve the quality. Computer in the device can process data automatically and display the results directly on the panel. It is high accurate, stable and easy-to-operate. 2. Technical Parameters 1. Accuracy: Cx±(reading×1%+1pF) other metal DF tgδ±(reading×1%+0.00040) PF cosφ±(reading×1%+0.00040) 2. Interference: Ratio of interference current to specimen ...
  • OEM Customized Hv Test And Measuring Machine -
 Power Cable Test Termination – LINT TOP

    OEM Customized Hv Test And Measuring Machine - Power Cable Test Termination – LINT TOP

    1. Introduction For power cable PD test, AC test, impulse test, tan delta test, etc. 2. Technical Parameters There are two types: 1. Oil test terminal (for XLPE cables under 35KV). 2. Deionized water terminal (for XLPE cables under 66KV-500KV). The water terminal consists of epoxy resin out and inter tube. The water at HV side cycles in the inner tube around the cable and back to outer tube. The terminal is fixed on movable base by bearing and hydraulic unit, and can rise to 45° for test. Cal...
  • OEM Factory for Partial Discharge Shielding Room -
 Power Cable Test Termination – LINT TOP

    OEM Factory for Partial Discharge Shielding Room - Power Cable Test Termination – LINT TOP

    1. Introduction For power cable PD test, AC test, impulse test, tan delta test, etc. 2. Technical Parameters There are two types: 1. Oil test terminal (for XLPE cables under 35KV). 2. Deionized water terminal (for XLPE cables under 66KV-500KV). The water terminal consists of epoxy resin out and inter tube. The water at HV side cycles in the inner tube around the cable and back to outer tube. The terminal is fixed on movable base by bearing and hydraulic unit, and can rise to 45° for test. Cal...
  • 2019 wholesale price High Voltage Test For Cables -
 High Frequency AC Spark Tester – LINT TOP

    2019 wholesale price High Voltage Test For Cables - High Frequency AC Spark Tester – LINT TOP

    1. Introduction High frequency AC spark tester is a fast and reliable tool widely used for online detection of wire and cable insulation and voltage resistance, holes and breaks. This is an important process that directly affects the quality of the entire cable. Compared with the traditional type, the machine has the advantages of space saving, easy operation and fast detection speed, and is more suitable for modern production. 2. Technical Parameters Model LT-015A LT-015B LT-015C ...
  • 2019 wholesale price High Voltage Test For Cables -
 AC Voltage Withstand Test System – LINT TOP

    2019 wholesale price High Voltage Test For Cables - AC Voltage Withstand Test System – LINT TOP

    1. Introduction The AC voltage test system is mainly used for power cable, electric transformer, HV  instrument transformer, HV switch, etc. The test items include AC voltage test, PD test  and electric aging test. 2. Components 1. Test transformer 2. LV filter 3. Coupling capacitor 4. Digital PD detector 5. Double shielded isolated transformer 6. HV capacitive divider 7. Contact type regulator 8. Digital control desk 3. Technical Parameters 1. Rated voltage: 1.0KV-1500KV (and above) 2. Rated...
  • Wholesale Price China Cable Heating Cycle Test System -
 Cable Heating Cycle Test System – LINT TOP

    Wholesale Price China Cable Heating Cycle Test System - Cable Heating Cycle Test System – LINT TOP

    1. Introduction The heavy current is used for testing power transformer, high voltage mutual inductor, arrester, high voltage XLPE cable and so on. It adopts heavy current load test to test sample with heavy current for judging the quality so that users can improve products quality. 2. Environment 1. Maximum altitude: 1500m 2. Temperature range: -5-+35℃ 3. Relative humidity(non-condensing): ≤90% 4. Temperature range of electronic component: 10-+40℃ 5. Relative humidity of electronic component...
  • China Cheap price Dc Spark Tester -
 Cable Heating Cycle Test System – LINT TOP

    China Cheap price Dc Spark Tester - Cable Heating Cycle Test System – LINT TOP

    1. Introduction The heavy current is used for testing power transformer, high voltage mutual inductor, arrester, high voltage XLPE cable and so on. It adopts heavy current load test to test sample with heavy current for judging the quality so that users can improve products quality. 2. Environment 1. Maximum altitude: 1500m 2. Temperature range: -5-+35℃ 3. Relative humidity(non-condensing): ≤90% 4. Temperature range of electronic component: 10-+40℃ 5. Relative humidity of electronic component...
  • Wholesale Withstand Voltage Test System -
 Laser Diameter Gauge – LINT TOP

    Wholesale Withstand Voltage Test System - Laser Diameter Gauge – LINT TOP

    1. Introduction The equipment is usually used to measure the diameter of the production line online, there are two types: Single-axis and double-axis. It can be equipped with remote feedback system and the feedback signal is sent to the host to control the stable operation of the whole production line. 2. Technical Parameters Model Effective Measuring Range (mm) Measuring Accuracy Structure LT-25 0.2-20 0.002±0.02%D Single-axis LT-60 0.4-45 0.003±0.02%D Single-ax...
  • OEM Manufacturer Shielding Room -
 Tanδ Measuring Bridge – LINT TOP

    OEM Manufacturer Shielding Room - Tanδ Measuring Bridge – LINT TOP

    1. Introduction The system is used for HV cable, power transformer, HV switch and so on. It judges quality of test sample by HV Tanδ test to improve the quality. Computer in the device can process data automatically and display the results directly on the panel. It is high accurate, stable and easy-to-operate. 2. Technical Parameters 1. Accuracy: Cx±(reading×1%+1pF) other metal DF tgδ±(reading×1%+0.00040) PF cosφ±(reading×1%+0.00040) 2. Interference: Ratio of interference current to specimen ...
  • Hot-selling Laser Diameter Gauge -
 Cable Heating Cycle Test System – LINT TOP

    Hot-selling Laser Diameter Gauge - Cable Heating Cycle Test System – LINT TOP

    1. Introduction The heavy current is used for testing power transformer, high voltage mutual inductor, arrester, high voltage XLPE cable and so on. It adopts heavy current load test to test sample with heavy current for judging the quality so that users can improve products quality. 2. Environment 1. Maximum altitude: 1500m 2. Temperature range: -5-+35℃ 3. Relative humidity(non-condensing): ≤90% 4. Temperature range of electronic component: 10-+40℃ 5. Relative humidity of electronic component...
  • Factory wholesale Horizontal Tensile Tester -
 Simplex & Duplex Indoor Optical Fiber Cable Production Line – LINT TOP

    Factory wholesale Horizontal Tensile Tester - Simplex & Duplex Indoor Optical Fiber Cable Production Line – LINT TOP

    1. Introduction Simplex and duplex indoor optical cables are suitable for the interconnection between instruments and communication equipment. It uses tight sleeve optical fiber, high-strength aramid reinforcement, with flame-retardant outer sheath structure. The structure of the optical cable is simple, with a small outer diameter and light weight; the all-dielectric structure is free from electromagnetic interference. It is easy to strip and use, so it has a very wide range of applications ...