cable testing machine

We believe that long expression partnership is often a result of top of the range, value added service, prosperous encounter and personal contact for cable testing machine, Tight Buffer Fiber Extruding Line , Sheathing Extrusion Line , shielding room , We believe that you will be glad with our realistic selling price, high-quality products and solutions and rapid delivery. We sincerely hope you can give us an prospect to provide you and be your best partner! To be a result of ours specialty and repair consciousness, our corporation has won an excellent reputation amongst customers all around the entire world for cable testing machine, Insisting on the high quality generation line management and customers expert assistance, we now have designed our resolution to supply our buyers using the to start with amount getting and just after services practical experience. Maintaining the prevailing friendly relations with our buyers, we however innovate our solution lists all of the time to satisfy the brand new demands and adhere to the most up-to-date development of the market in Malta. We have been ready to face the worries and make the improve to understand all the possibilities in international trade.


  • Cable Heating Cycle Test System

    Cable Heating Cycle Test System

    1. Introduction The heavy current is used for testing power transformer, high voltage mutual inductor, arrester, high voltage XLPE cable and so on. It adopts heavy current load test to test sample with heavy current for judging the quality so that users can improve products quality. 2. Environment 1. Maximum altitude: 1500m 2. Temperature range: -5-+35℃ 3. Relative humidity(non-condensing): ≤90% 4. Temperature range of electronic component: 10-+40℃ 5. Relative humidity of electronic component...
  • Power Cable Test Termination

    Power Cable Test Termination

    1. Introduction For power cable PD test, AC test, impulse test, tan delta test, etc. 2. Technical Parameters There are two types: 1. Oil test terminal (for XLPE cables under 35KV). 2. Deionized water terminal (for XLPE cables under 66KV-500KV). The water terminal consists of epoxy resin out and inter tube. The water at HV side cycles in the inner tube around the cable and back to outer tube. The terminal is fixed on movable base by bearing and hydraulic unit, and can rise to 45° for test. Cal...
  • OEM Factory for Partial Discharge Shielding Room -
 High Frequency AC Spark Tester – LINT TOP

    OEM Factory for Partial Discharge Shielding Room - High Frequency AC Spark Tester – LINT TOP

    1. Introduction High frequency AC spark tester is a fast and reliable tool widely used for online detection of wire and cable insulation and voltage resistance, holes and breaks. This is an important process that directly affects the quality of the entire cable. Compared with the traditional type, the machine has the advantages of space saving, easy operation and fast detection speed, and is more suitable for modern production. 2. Technical Parameters Model LT-015A LT-015B LT-015C ...
  • OEM/ODM Manufacturer Heat Cycling Test System -
 Cable Heating Cycle Test System – LINT TOP

    OEM/ODM Manufacturer Heat Cycling Test System - Cable Heating Cycle Test System – LINT TOP

    1. Introduction The heavy current is used for testing power transformer, high voltage mutual inductor, arrester, high voltage XLPE cable and so on. It adopts heavy current load test to test sample with heavy current for judging the quality so that users can improve products quality. 2. Environment 1. Maximum altitude: 1500m 2. Temperature range: -5-+35℃ 3. Relative humidity(non-condensing): ≤90% 4. Temperature range of electronic component: 10-+40℃ 5. Relative humidity of electronic component...
  • 100% Original Spark Tester -
 HV Shielded Test Room – LINT TOP

    100% Original Spark Tester - HV Shielded Test Room – LINT TOP

    1. Introduction The HV partial discharge hall is mainly used for power transformer, HV inductor, arrester, HV switch, HV XLPE cable and so on, the shielded room is used for avoiding electromagnetic interference which can affect partial discharge test. 2. Technical Parameters Rated Voltage (kV) ±100-2000 (and above) Exterior Dimension (m) 60*40*30(L*W*H)(bigger size is available) Grounding Resistor Requirement<1.0Ω Insulating Resistance ≤10KΩ(measured after completin...
  • Manufacturer for Cable Testing Equipment -
 Tanδ Measuring Bridge – LINT TOP

    Manufacturer for Cable Testing Equipment - Tanδ Measuring Bridge – LINT TOP

    1. Introduction The system is used for HV cable, power transformer, HV switch and so on. It judges quality of test sample by HV Tanδ test to improve the quality. Computer in the device can process data automatically and display the results directly on the panel. It is high accurate, stable and easy-to-operate. 2. Technical Parameters 1. Accuracy: Cx±(reading×1%+1pF) other metal DF tgδ±(reading×1%+0.00040) PF cosφ±(reading×1%+0.00040) 2. Interference: Ratio of interference current to specimen ...
  • OEM Supply Hv Shielded Test Room -
 AC Voltage Withstand Test System – LINT TOP

    OEM Supply Hv Shielded Test Room - AC Voltage Withstand Test System – LINT TOP

    1. Introduction The AC voltage test system is mainly used for power cable, electric transformer, HV  instrument transformer, HV switch, etc. The test items include AC voltage test, PD test  and electric aging test. 2. Components 1. Test transformer 2. LV filter 3. Coupling capacitor 4. Digital PD detector 5. Double shielded isolated transformer 6. HV capacitive divider 7. Contact type regulator 8. Digital control desk 3. Technical Parameters 1. Rated voltage: 1.0KV-1500KV (and above) 2. Rated...
  • OEM/ODM Factory Cable Testing Machine -
 Tanδ Measuring Bridge – LINT TOP

    OEM/ODM Factory Cable Testing Machine - Tanδ Measuring Bridge – LINT TOP

    1. Introduction The system is used for HV cable, power transformer, HV switch and so on. It judges quality of test sample by HV Tanδ test to improve the quality. Computer in the device can process data automatically and display the results directly on the panel. It is high accurate, stable and easy-to-operate. 2. Technical Parameters 1. Accuracy: Cx±(reading×1%+1pF) other metal DF tgδ±(reading×1%+0.00040) PF cosφ±(reading×1%+0.00040) 2. Interference: Ratio of interference current to specimen ...
  • 8 Year Exporter Sf6 Gas Filled Standard Capacitor -
 AC Resonance PD Free Test System – LINT TOP

    8 Year Exporter Sf6 Gas Filled Standard Capacitor - AC Resonance PD Free Test System – LINT TOP

    Compared with overhead lines, cable lines have the advantages of concealed laying, less climate interference, less maintenance, and less impact on the city’s city appearance, and their application in urban power grids is becoming more and more common. Among them, cross-linked polyethylene (XLPE) power cables have become mainstream cables because of their good electrical mechanical performance, large transmission capacity, and flexible construction and installation. Long-distance high-vo...
  • OEM/ODM China Cables Sparkle Testing Equipment -
 Laser Diameter Gauge – LINT TOP

    OEM/ODM China Cables Sparkle Testing Equipment - Laser Diameter Gauge – LINT TOP

    1. Introduction The equipment is usually used to measure the diameter of the production line online, there are two types: Single-axis and double-axis. It can be equipped with remote feedback system and the feedback signal is sent to the host to control the stable operation of the whole production line. 2. Technical Parameters Model Effective Measuring Range (mm) Measuring Accuracy Structure LT-25 0.2-20 0.002±0.02%D Single-axis LT-60 0.4-45 0.003±0.02%D Single-ax...
  • Professional China High Frequency Ac Spark Tester -
 HV Shielded Test Room – LINT TOP

    Professional China High Frequency Ac Spark Tester - HV Shielded Test Room – LINT TOP

    1. Introduction The HV partial discharge hall is mainly used for power transformer, HV inductor, arrester, HV switch, HV XLPE cable and so on, the shielded room is used for avoiding electromagnetic interference which can affect partial discharge test. 2. Technical Parameters Rated Voltage (kV) ±100-2000 (and above) Exterior Dimension (m) 60*40*30(L*W*H)(bigger size is available) Grounding Resistor Requirement<1.0Ω Insulating Resistance ≤10KΩ(measured after completin...
  • OEM Customized Hv Test And Measuring Machine -
 Power Cable Test Termination – LINT TOP

    OEM Customized Hv Test And Measuring Machine - Power Cable Test Termination – LINT TOP

    1. Introduction For power cable PD test, AC test, impulse test, tan delta test, etc. 2. Technical Parameters There are two types: 1. Oil test terminal (for XLPE cables under 35KV). 2. Deionized water terminal (for XLPE cables under 66KV-500KV). The water terminal consists of epoxy resin out and inter tube. The water at HV side cycles in the inner tube around the cable and back to outer tube. The terminal is fixed on movable base by bearing and hydraulic unit, and can rise to 45° for test. Cal...